@@ -1,19 +1,24 @@
# win_perf_counters readme
The way this plugin works is that on load of Telegraf,
the plugin will be handed configuration from Telegraf.
This configuration is parsed and then tested for validity such as
if the Object, Instance and Counter existing.
If it does not match at startup, it will not be fetched.
Exceptions to this are in cases where you query for all instances "*".
By default the plugin does not return _Total
when it is querying for all (*) as this is redundant.
Input plugin to read Performance Counters on Windows operating systems.
Configuration is parsed and then tested for validity such as
whether the Object, Instance and Counter exist on Telegraf startup.
Counter paths are refreshed periodically, see [CountersRefreshInterval](#countersrefreshinterval)
configuration parameter for more info.
Wildcards can be used in instance and counter names. Partial wildcards are supported only
in instance names on Windows Vista and newer.
In case of query for all instances `["*"]`, the plugin does not return the instance `_Total`
by default. See [IncludeTotal](#includetotal) for more info.
## Basics
The examples contained in this file have been found on the internet
as counters used when performance monitoring
Active Directory and IIS in perticular.
Active Directory and IIS in particular.
There are a lot other good objects to monitor, if you know what to look for.
This file is likely to be updated in the future with more examples for
useful configurations for separate scenarios.
@@ -29,9 +34,23 @@ Bool, if set to `true` will print out all matching performance objects.
Example:
`PrintValid=true`
#### CountersRefreshInterval
Configured counters are matched against available counters at the interval
specified by the `CountersRefreshInterval` parameter. Default value is `1m` (1 minute).
If wildcards are used in instance or counter names, they are expanded at this point.
Setting `CountersRefreshInterval` too low (order of seconds) can cause Telegraf to create
a high CPU load.
Set to `0s` to disable periodic refreshing.
#### PreVistaSupport
Bool, if set to `true` will use the localized PerfCounter interface that is present before Vista for backwards compatability.
_Deprecated. Necessary features on Windows Vista and newer are checked dynamically_
Bool, if set to `true` will use the localized PerfCounter interface that has been present since before Vista for backwards compatability.
It is recommended NOT to use this on OSes starting with Vista and newer because it requires more configuration to use this than the newer interface present since Vista.
@@ -45,10 +64,10 @@ See Entry below.
### Entry
A new configuration entry consists of the TOML header to start with,
`[[inputs.win_perf_counters.object]]`.
This must follow before other plugins configuration,
This must follow before other plugin configurations,
beneath the main win_perf_counters entry, `[[inputs.win_perf_counters]]`.
Following this is 3 required key/value pairs and the three optional parameters and their usage.
Following this are 3 required key/value pairs and the three optional parameters and their usage.
#### ObjectName
**Required**
@@ -60,37 +79,39 @@ Example: `ObjectName = "LogicalDisk"`
#### Instances
**Required**
Instances (this is an array) is the instances of a counter you would like returned,
Instances key (this is an array) is the instances of a counter you would like returned,
it can be one or more values.
Example, `Instances = ["C:","D:","E:"]` will return only for the instances
C:, D: and E: where relevant. To get all instances of a Counter, use ["*"] only.
By default any results containing _Total are stripped,
C:, D: and E: where relevant. To get all instances of a Counter, use `["*"]` only.
By default any results containing `_Total` are stripped,
unless this is specified as the wanted instance.
Alternatively see the option IncludeTotal below.
Alternatively see the option `IncludeTotal` below.
Some Objects does not have instances to select from at all,
here only one option is valid if you want data back,
It is also possible to set partial wildcards, eg. `["chrome*"]`
Some Objects do not have instances to select from at all.
Here only one option is valid if you want data back,
and that is to specify `Instances = ["------"]`.
#### Counters
**Required**
Counters (this is an array) is the counters of the ObjectName
Counters key (this is an array) is the counters of the ObjectName
you would like returned, it can also be one or more values.
Example: `Counters = ["% Idle Time", "% Disk Read Time", "% Disk Write Time"]`
This must be specified for every counter you want the results of,
it is not possible to ask for all counters in the ObjectName.
or use `["*"]` for all the counters for object.
#### Measurement
*Optional*
This key is optional, if it is not set it will be win_perf_counters.
This key is optional, if it is not set it will be `win_perf_counters`.
In InfluxDB this is the key by which the returned data is stored underneath,
so for ordering your data in a good manner,
this is a good key to set with where you want your IIS and Disk results stored,
separate from Processor results.
this is a good key to set with a value when you want your IIS and Disk results stored
separately from Processor results.
Example: `Measurement = "win_disk"
@@ -99,9 +120,9 @@ Example: `Measurement = "win_disk"
This key is optional, it is a simple bool.
If it is not set to true or included it is treated as false.
This key only has an effect if Instances is set to "*"
and you would also like all instances containg _Total returned,
like "_Total", "0,_Total" and so on where applicable
This key only has an effect if the Instances key is set to `["*"]`
and you would also like all instances containing `_Total` returned,
like `_Total`, `0,_Total` and so on where applicable
(Processor Information is one example).
#### WarnOnMissing
@@ -111,13 +132,13 @@ This key is optional, it is a simple bool.
If it is not set to true or included it is treated as false.
This only has an effect on the first execution of the plugin,
it will print out any ObjectName/Instance/Counter combinations
asked for that does not match. Useful when debugging new configurations.
asked for that do not match. Useful when debugging new configurations.
#### FailOnMissing
*Internal*
This key should not be used, it is for testing purposes only.
It is a simple bool, if it is not set to true or included this is treaded as false.
This key should not be used. It is for testing purposes only.
It is a simple bool. If it is not set to true or included this is treated as false.
If this is set to true, the plugin will abort and end prematurely
if any of the combinations of ObjectName/Instances/Counters are invalid.
@@ -337,10 +358,14 @@ if any of the combinations of ObjectName/Instances/Counters are invalid.
## Troubleshooting
If you are getting an error about an invalid counter, use the `typeperf` command to check the counter path
on the command line.
E.g. `typeperf "Process(chrome*)\% Processor Time"`
If no metrics are emitted even with the default config, you may need to repair
your performance counters.
1. Launch Command Prompt as Administrator (right click Runs As Administrator).
1. Launch the Command Prompt as Administrator (right click Runs As Administrator).
1. Drop into the C:\WINDOWS\System32 directory by typing `C:` then `cd \Windows\System32`
1. Rebuild your counter values, which may take a few moments so please be
patient, by running: