[SNMP Input] SNMPMap() loops forever if table has more than 32 entries
This commit is contained in:
parent
35f1e28809
commit
1c36781c84
|
@ -464,13 +464,14 @@ func (h *Host) SNMPMap(acc telegraf.Accumulator) error {
|
|||
// To get mapping between instance id
|
||||
// and instance name
|
||||
oid_asked := table.mappingTable
|
||||
oid_next := oid_asked
|
||||
need_more_requests := true
|
||||
// Set max repetition
|
||||
maxRepetition := uint8(32)
|
||||
// Launch requests
|
||||
for need_more_requests {
|
||||
// Launch request
|
||||
result, err3 := snmpClient.GetBulk([]string{oid_asked}, 0, maxRepetition)
|
||||
result, err3 := snmpClient.GetBulk([]string{oid_next}, 0, maxRepetition)
|
||||
if err3 != nil {
|
||||
return err3
|
||||
}
|
||||
|
@ -572,6 +573,7 @@ func (h *Host) SNMPMap(acc telegraf.Accumulator) error {
|
|||
// Determine if we need more requests
|
||||
if strings.HasPrefix(lastOid, oid_asked) {
|
||||
need_more_requests = true
|
||||
oid_next = lastOid
|
||||
} else {
|
||||
need_more_requests = false
|
||||
}
|
||||
|
|
Loading…