Add possibility to specify measurement per register (#7231)
This commit is contained in:
parent
9a1c26d6cc
commit
3650d74de2
|
@ -12,17 +12,17 @@ The Modbus plugin collects Discrete Inputs, Coils, Input Registers and Holding R
|
||||||
##
|
##
|
||||||
## Device name
|
## Device name
|
||||||
name = "Device"
|
name = "Device"
|
||||||
|
|
||||||
## Slave ID - addresses a MODBUS device on the bus
|
## Slave ID - addresses a MODBUS device on the bus
|
||||||
## Range: 0 - 255 [0 = broadcast; 248 - 255 = reserved]
|
## Range: 0 - 255 [0 = broadcast; 248 - 255 = reserved]
|
||||||
slave_id = 1
|
slave_id = 1
|
||||||
|
|
||||||
## Timeout for each request
|
## Timeout for each request
|
||||||
timeout = "1s"
|
timeout = "1s"
|
||||||
|
|
||||||
# TCP - connect via Modbus/TCP
|
# TCP - connect via Modbus/TCP
|
||||||
controller = "tcp://localhost:502"
|
controller = "tcp://localhost:502"
|
||||||
|
|
||||||
# Serial (RS485; RS232)
|
# Serial (RS485; RS232)
|
||||||
#controller = "file:///dev/ttyUSB0"
|
#controller = "file:///dev/ttyUSB0"
|
||||||
#baud_rate = 9600
|
#baud_rate = 9600
|
||||||
|
@ -30,15 +30,15 @@ The Modbus plugin collects Discrete Inputs, Coils, Input Registers and Holding R
|
||||||
#parity = "N"
|
#parity = "N"
|
||||||
#stop_bits = 1
|
#stop_bits = 1
|
||||||
#transmission_mode = "RTU"
|
#transmission_mode = "RTU"
|
||||||
|
|
||||||
|
|
||||||
## Measurements
|
## Measurements
|
||||||
##
|
##
|
||||||
|
|
||||||
## Digital Variables, Discrete Inputs and Coils
|
## Digital Variables, Discrete Inputs and Coils
|
||||||
## name - the variable name
|
## name - the variable name
|
||||||
## address - variable address
|
## address - variable address
|
||||||
|
|
||||||
discrete_inputs = [
|
discrete_inputs = [
|
||||||
{ name = "Start", address = [0]},
|
{ name = "Start", address = [0]},
|
||||||
{ name = "Stop", address = [1]},
|
{ name = "Stop", address = [1]},
|
||||||
|
@ -49,11 +49,12 @@ The Modbus plugin collects Discrete Inputs, Coils, Input Registers and Holding R
|
||||||
{ name = "Motor1-Run", address = [0]},
|
{ name = "Motor1-Run", address = [0]},
|
||||||
{ name = "Motor1-Jog", address = [1]},
|
{ name = "Motor1-Jog", address = [1]},
|
||||||
{ name = "Motor1-Stop", address = [2]},
|
{ name = "Motor1-Stop", address = [2]},
|
||||||
]
|
]
|
||||||
|
|
||||||
## Analog Variables, Input Registers and Holding Registers
|
## Analog Variables, Input Registers and Holding Registers
|
||||||
|
## measurement - the (optional) measurement name, defaults to "modbus"
|
||||||
## name - the variable name
|
## name - the variable name
|
||||||
## byte_order - the ordering of bytes
|
## byte_order - the ordering of bytes
|
||||||
## |---AB, ABCD - Big Endian
|
## |---AB, ABCD - Big Endian
|
||||||
## |---BA, DCBA - Little Endian
|
## |---BA, DCBA - Little Endian
|
||||||
## |---BADC - Mid-Big Endian
|
## |---BADC - Mid-Big Endian
|
||||||
|
@ -61,7 +62,7 @@ The Modbus plugin collects Discrete Inputs, Coils, Input Registers and Holding R
|
||||||
## data_type - INT16, UINT16, INT32, UINT32, INT64, UINT64, FLOAT32, FLOAT32-IEEE (the IEEE 754 binary representation)
|
## data_type - INT16, UINT16, INT32, UINT32, INT64, UINT64, FLOAT32, FLOAT32-IEEE (the IEEE 754 binary representation)
|
||||||
## scale - the final numeric variable representation
|
## scale - the final numeric variable representation
|
||||||
## address - variable address
|
## address - variable address
|
||||||
|
|
||||||
holding_registers = [
|
holding_registers = [
|
||||||
{ name = "PowerFactor", byte_order = "AB", data_type = "FLOAT32", scale=0.01, address = [8]},
|
{ name = "PowerFactor", byte_order = "AB", data_type = "FLOAT32", scale=0.01, address = [8]},
|
||||||
{ name = "Voltage", byte_order = "AB", data_type = "FLOAT32", scale=0.1, address = [0]},
|
{ name = "Voltage", byte_order = "AB", data_type = "FLOAT32", scale=0.1, address = [0]},
|
||||||
|
|
|
@ -7,10 +7,12 @@ import (
|
||||||
"net"
|
"net"
|
||||||
"net/url"
|
"net/url"
|
||||||
"sort"
|
"sort"
|
||||||
|
"time"
|
||||||
|
|
||||||
mb "github.com/goburrow/modbus"
|
mb "github.com/goburrow/modbus"
|
||||||
"github.com/influxdata/telegraf"
|
"github.com/influxdata/telegraf"
|
||||||
"github.com/influxdata/telegraf/internal"
|
"github.com/influxdata/telegraf/internal"
|
||||||
|
"github.com/influxdata/telegraf/metric"
|
||||||
"github.com/influxdata/telegraf/plugins/inputs"
|
"github.com/influxdata/telegraf/plugins/inputs"
|
||||||
)
|
)
|
||||||
|
|
||||||
|
@ -44,12 +46,13 @@ type register struct {
|
||||||
}
|
}
|
||||||
|
|
||||||
type fieldContainer struct {
|
type fieldContainer struct {
|
||||||
Name string `toml:"name"`
|
Measurement string `toml:"measurement"`
|
||||||
ByteOrder string `toml:"byte_order"`
|
Name string `toml:"name"`
|
||||||
DataType string `toml:"data_type"`
|
ByteOrder string `toml:"byte_order"`
|
||||||
Scale float64 `toml:"scale"`
|
DataType string `toml:"data_type"`
|
||||||
Address []uint16 `toml:"address"`
|
Scale float64 `toml:"scale"`
|
||||||
value interface{}
|
Address []uint16 `toml:"address"`
|
||||||
|
value interface{}
|
||||||
}
|
}
|
||||||
|
|
||||||
type registerRange struct {
|
type registerRange struct {
|
||||||
|
@ -97,14 +100,15 @@ const sampleConfig = `
|
||||||
##
|
##
|
||||||
|
|
||||||
## Digital Variables, Discrete Inputs and Coils
|
## Digital Variables, Discrete Inputs and Coils
|
||||||
## name - the variable name
|
## measurement - the (optional) measurement name, defaults to "modbus"
|
||||||
## address - variable address
|
## name - the variable name
|
||||||
|
## address - variable address
|
||||||
|
|
||||||
discrete_inputs = [
|
discrete_inputs = [
|
||||||
{ name = "start", address = [0]},
|
{ name = "start", address = [0]},
|
||||||
{ name = "stop", address = [1]},
|
{ name = "stop", address = [1]},
|
||||||
{ name = "reset", address = [2]},
|
{ name = "reset", address = [2]},
|
||||||
{ name = "emergency_stop", address = [3]},
|
{ name = "emergency_stop", address = [3]},
|
||||||
]
|
]
|
||||||
coils = [
|
coils = [
|
||||||
{ name = "motor1_run", address = [0]},
|
{ name = "motor1_run", address = [0]},
|
||||||
|
@ -113,8 +117,9 @@ const sampleConfig = `
|
||||||
]
|
]
|
||||||
|
|
||||||
## Analog Variables, Input Registers and Holding Registers
|
## Analog Variables, Input Registers and Holding Registers
|
||||||
## name - the variable name
|
## measurement - the (optional) measurement name, defaults to "modbus"
|
||||||
## byte_order - the ordering of bytes
|
## name - the variable name
|
||||||
|
## byte_order - the ordering of bytes
|
||||||
## |---AB, ABCD - Big Endian
|
## |---AB, ABCD - Big Endian
|
||||||
## |---BA, DCBA - Little Endian
|
## |---BA, DCBA - Little Endian
|
||||||
## |---BADC - Mid-Big Endian
|
## |---BADC - Mid-Big Endian
|
||||||
|
@ -134,7 +139,7 @@ const sampleConfig = `
|
||||||
input_registers = [
|
input_registers = [
|
||||||
{ name = "tank_level", byte_order = "AB", data_type = "INT16", scale=1.0, address = [0]},
|
{ name = "tank_level", byte_order = "AB", data_type = "INT16", scale=1.0, address = [0]},
|
||||||
{ name = "tank_ph", byte_order = "AB", data_type = "INT16", scale=1.0, address = [1]},
|
{ name = "tank_ph", byte_order = "AB", data_type = "INT16", scale=1.0, address = [1]},
|
||||||
{ name = "pump1_speed", byte_order = "ABCD", data_type = "INT32", scale=1.0, address = [3,4]},
|
{ name = "pump1_speed", byte_order = "ABCD", data_type = "INT32", scale=1.0, address = [3,4]},
|
||||||
]
|
]
|
||||||
`
|
`
|
||||||
|
|
||||||
|
@ -319,10 +324,11 @@ func validateFieldContainers(t []fieldContainer, n string) error {
|
||||||
}
|
}
|
||||||
|
|
||||||
//search name duplicate
|
//search name duplicate
|
||||||
if nameEncountered[item.Name] {
|
canonical_name := item.Measurement + "." + item.Name
|
||||||
return fmt.Errorf("name '%s' is duplicated in '%s' - '%s'", item.Name, n, item.Name)
|
if nameEncountered[canonical_name] {
|
||||||
|
return fmt.Errorf("name '%s' is duplicated in measurement '%s' '%s' - '%s'", item.Name, item.Measurement, n, item.Name)
|
||||||
} else {
|
} else {
|
||||||
nameEncountered[item.Name] = true
|
nameEncountered[canonical_name] = true
|
||||||
}
|
}
|
||||||
|
|
||||||
if n == cInputRegisters || n == cHoldingRegisters {
|
if n == cInputRegisters || n == cHoldingRegisters {
|
||||||
|
@ -635,6 +641,7 @@ func (m *Modbus) Gather(acc telegraf.Accumulator) error {
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
timestamp := time.Now()
|
||||||
err := m.getFields()
|
err := m.getFields()
|
||||||
if err != nil {
|
if err != nil {
|
||||||
disconnect(m)
|
disconnect(m)
|
||||||
|
@ -642,18 +649,28 @@ func (m *Modbus) Gather(acc telegraf.Accumulator) error {
|
||||||
return err
|
return err
|
||||||
}
|
}
|
||||||
|
|
||||||
|
grouper := metric.NewSeriesGrouper()
|
||||||
for _, reg := range m.registers {
|
for _, reg := range m.registers {
|
||||||
fields := make(map[string]interface{})
|
|
||||||
tags := map[string]string{
|
tags := map[string]string{
|
||||||
"name": m.Name,
|
"name": m.Name,
|
||||||
"type": reg.Type,
|
"type": reg.Type,
|
||||||
}
|
}
|
||||||
|
|
||||||
for _, field := range reg.Fields {
|
for _, field := range reg.Fields {
|
||||||
fields[field.Name] = field.value
|
// In case no measurement was specified we use "modbus" as default
|
||||||
|
measurement := "modbus"
|
||||||
|
if field.Measurement != "" {
|
||||||
|
measurement = field.Measurement
|
||||||
|
}
|
||||||
|
|
||||||
|
// Group the data by series
|
||||||
|
grouper.Add(measurement, tags, timestamp, field.Name, field.value)
|
||||||
}
|
}
|
||||||
|
|
||||||
acc.AddFields("modbus", fields, tags)
|
// Add the metrics grouped by series to the accumulator
|
||||||
|
for _, metric := range grouper.Metrics() {
|
||||||
|
acc.AddMetric(metric)
|
||||||
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
return nil
|
return nil
|
||||||
|
|
Loading…