# IPMI Sensor Input Plugin Get bare metal metrics using the command line utility [`ipmitool`](https://sourceforge.net/projects/ipmitool/files/ipmitool/). If no servers are specified, the plugin will query the local machine sensor stats via the following command: ``` ipmitool sdr ``` When one or more servers are specified, the plugin will use the following command to collect remote host sensor stats: ``` ipmitool -I lan -H SERVER -U USERID -P PASSW0RD sdr ``` ### Configuration ```toml # Read metrics from the bare metal servers via IPMI [[inputs.ipmi_sensor]] ## optionally specify the path to the ipmitool executable # path = "/usr/bin/ipmitool" # ## optionally specify one or more servers via a url matching ## [username[:password]@][protocol[(address)]] ## e.g. ## root:passwd@lan(127.0.0.1) ## ## if no servers are specified, local machine sensor stats will be queried ## # servers = ["USERID:PASSW0RD@lan(192.168.1.1)"] ## Recomended: use metric 'interval' that is a multiple of 'timeout' to avoid ## gaps or overlap in pulled data interval = "30s" ## Timeout for the ipmitool command to complete. Default is 20 seconds. timeout = "20s" ``` ### Measurements - ipmi_sensor: - tags: - name - unit - server (only when retrieving stats from remote servers) - fields: - status (int) - value (float) #### Permissions When gathering from the local system, Telegraf will need permission to the ipmi device node. When using udev you can create the device node giving `rw` permissions to the `telegraf` user by adding the following rule to `/etc/udev/rules.d/52-telegraf-ipmi.rules`: ``` KERNEL=="ipmi*", MODE="660", GROUP="telegraf" ``` ### Example Output When retrieving stats from a remote server: ``` ipmi_sensor,server=10.20.2.203,unit=degrees_c,name=ambient_temp status=1i,value=20 1458488465012559455 ipmi_sensor,server=10.20.2.203,unit=feet,name=altitude status=1i,value=80 1458488465012688613 ipmi_sensor,server=10.20.2.203,unit=watts,name=avg_power status=1i,value=220 1458488465012776511 ipmi_sensor,server=10.20.2.203,unit=volts,name=planar_3.3v status=1i,value=3.28 1458488465012861875 ipmi_sensor,server=10.20.2.203,unit=volts,name=planar_vbat status=1i,value=3.04 1458488465013072508 ipmi_sensor,server=10.20.2.203,unit=rpm,name=fan_1a_tach status=1i,value=2610 1458488465013137932 ipmi_sensor,server=10.20.2.203,unit=rpm,name=fan_1b_tach status=1i,value=1775 1458488465013279896 ``` When retrieving stats from the local machine (no server specified): ``` ipmi_sensor,unit=degrees_c,name=ambient_temp status=1i,value=20 1458488465012559455 ipmi_sensor,unit=feet,name=altitude status=1i,value=80 1458488465012688613 ipmi_sensor,unit=watts,name=avg_power status=1i,value=220 1458488465012776511 ipmi_sensor,unit=volts,name=planar_3.3v status=1i,value=3.28 1458488465012861875 ipmi_sensor,unit=volts,name=planar_vbat status=1i,value=3.04 1458488465013072508 ipmi_sensor,unit=rpm,name=fan_1a_tach status=1i,value=2610 1458488465013137932 ipmi_sensor,unit=rpm,name=fan_1b_tach status=1i,value=1775 1458488465013279896 ```