# SNMP2 Plugin The SNMP2 input plugin gathers metrics from SNMP agents. It is an alternative to the SNMP plugin with significantly different configuration & behavior. ## Configuration: ### Example: SNMP data: ``` .1.2.3.0.0.1.0 octet_str "foo" .1.2.3.0.0.1.1 octet_str "bar" .1.2.3.0.0.102 octet_str "bad" .1.2.3.0.0.2.0 integer 1 .1.2.3.0.0.2.1 integer 2 .1.2.3.0.0.3.0 octet_str "0.123" .1.2.3.0.0.3.1 octet_str "0.456" .1.2.3.0.0.3.2 octet_str "9.999" .1.2.3.0.1 octet_str "baz" .1.2.3.0.2 uinteger 54321 .1.2.3.0.3 uinteger 234 ``` Telegraf config: ```toml [[inputs.snmp2]] agents = [ "127.0.0.1:161" ] version = 2 community = "public" name = "system" [[inputs.snmp2.field]] name = "hostname" oid = ".1.2.3.0.1" is_tag = true [[inputs.snmp2.field]] name = "uptime" oid = ".1.2.3.0.2" [[inputs.snmp2.field]] name = "loadavg" oid = ".1.2.3.0.3" conversion = "float(2)" [[inputs.snmp2.table]] name = "remote_servers" inherit_tags = [ "hostname" ] [[inputs.snmp2.table.field]] name = "server" oid = ".1.2.3.0.0.1" is_tag = true [[inputs.snmp2.table.field]] name = "connections" oid = ".1.2.3.0.0.2" [[inputs.snmp2.table.field]] name = "latency" oid = ".1.2.3.0.0.3" conversion = "float" ``` Resulting output: ``` * Plugin: snmp2, Collection 1 > system,agent_host=127.0.0.1,host=mylocalhost,hostname=baz loadavg=2.34,uptime=54321i 1468953135000000000 > remote_servers,agent_host=127.0.0.1,host=mylocalhost,hostname=baz,server=foo connections=1i,latency=0.123 1468953135000000000 > remote_servers,agent_host=127.0.0.1,host=mylocalhost,hostname=baz,server=bar connections=2i,latency=0.456 1468953135000000000 ``` ### Config parameters * `agents`: Default: `[]` List of SNMP agents to connect to in the form of `IP[:PORT]`. If `:PORT` is unspecified, it defaults to `161`. * `version`: Default: `2` SNMP protocol version to use. * `community`: Default: `"public"` SNMP community to use. * `max_repetitions`: Default: `50` Maximum number of iterations for repeating variables. * `sec_name`: Security name for authenticated SNMPv3 requests. * `auth_protocol`: Values: `"MD5"`,`"SHA"`,`""`. Default: `""` Authentication protocol for authenticated SNMPv3 requests. * `auth_password`: Authentication password for authenticated SNMPv3 requests. * `sec_level`: Values: `"noAuthNoPriv"`,`"authNoPriv"`,`"authPriv"`. Default: `"noAuthNoPriv"` Security level used for SNMPv3 messages. * `context_name`: Context name used for SNMPv3 requests. * `priv_protocol`: Values: `"DES"`,`"AES"`,`""`. Default: `""` Privacy protocol used for encrypted SNMPv3 messages. * `priv_password`: Privacy password used for encrypted SNMPv3 messages. * `name`: Output measurement name. #### Field parameters: * `name`: Output field/tag name. * `oid`: OID to get. Must be in dotted notation, not textual. * `is_tag`: Output this field as a tag. * `conversion`: Values: `"float(X)"`,`"float"`,`"int"`,`""`. Default: `""` Converts the value according to the given specification. - `float(X)`: Converts the input value into a float and divides by the Xth power of 10. Efficively just moves the decimal left X places. For example a value of `123` with `float(2)` will result in `1.23`. - `float`: Converts the value into a float with no adjustment. Same as `float(0)`. - `int`: Convertes the value into an integer. #### Table parameters: * `name`: Output measurement name. * `inherit_tags`: Which tags to inherit from the top-level config and to use in the output of this table's measurement.