telegraf/plugins/inputs/ipmi_sensor
Robpol86 56aa89e5c8 Exporting Ipmi.Path to be set by config. (#2498)
* Exporting Ipmi.Path to be set by config.

Currently "path" is not exported, giving this error when users try to
override the variable via telegraf.conf as per the sample config:

`field corresponding to `path' is not defined in `*ipmi_sensor.Ipmi'`

Exporting the variable solves the problem.

* Updating changelog.
2017-03-08 16:38:36 +00:00
..
README.md allow querying sensors via the open interface 2017-02-02 13:31:04 +00:00
connection.go allow querying sensors via the open interface 2017-02-02 13:31:04 +00:00
ipmi.go Exporting Ipmi.Path to be set by config. (#2498) 2017-03-08 16:38:36 +00:00
ipmi_test.go Exporting Ipmi.Path to be set by config. (#2498) 2017-03-08 16:38:36 +00:00

README.md

Telegraf ipmi plugin

Get bare metal metrics using the command line utility ipmitool

see ipmitool(https://sourceforge.net/projects/ipmitool/files/ipmitool/)

If no servers are specified, the plugin will query the local machine sensor stats via the following command:

ipmitool sdr

When one or more servers are specified, the plugin will use the following command to collect remote host sensor stats:

ipmitool -I lan -H SERVER -U USERID -P PASSW0RD sdr

Measurements

  • ipmi_sensor:

    • Tags: name, unit
    • Fields:
      • status
      • value

The server tag will be made available when retrieving stats from remote server(s).

Configuration

# Read metrics from the bare metal servers via IPMI
[[inputs.ipmi_sensor]]
  ## optionally specify the path to the ipmitool executable
  # path = "/usr/bin/ipmitool"
  #
  ## optionally specify one or more servers via a url matching
  ##  [username[:password]@][protocol[(address)]]
  ##  e.g.
  ##    root:passwd@lan(127.0.0.1)
  ##
  ## if no servers are specified, local machine sensor stats will be queried
  ##
  # servers = ["USERID:PASSW0RD@lan(192.168.1.1)"]

Output

When retrieving stats from a remote server:

> ipmi_sensor,server=10.20.2.203,unit=degrees_c,name=ambient_temp status=1i,value=20 1458488465012559455
> ipmi_sensor,server=10.20.2.203,unit=feet,name=altitude status=1i,value=80 1458488465012688613
> ipmi_sensor,server=10.20.2.203,unit=watts,name=avg_power status=1i,value=220 1458488465012776511
> ipmi_sensor,server=10.20.2.203,unit=volts,name=planar_3.3v status=1i,value=3.28 1458488465012861875
> ipmi_sensor,server=10.20.2.203,unit=volts,name=planar_vbat status=1i,value=3.04 1458488465013072508
> ipmi_sensor,server=10.20.2.203,unit=rpm,name=fan_1a_tach status=1i,value=2610 1458488465013137932
> ipmi_sensor,server=10.20.2.203,unit=rpm,name=fan_1b_tach status=1i,value=1775 1458488465013279896

When retrieving stats from the local machine (no server specified):

> ipmi_sensor,unit=degrees_c,name=ambient_temp status=1i,value=20 1458488465012559455
> ipmi_sensor,unit=feet,name=altitude status=1i,value=80 1458488465012688613
> ipmi_sensor,unit=watts,name=avg_power status=1i,value=220 1458488465012776511
> ipmi_sensor,unit=volts,name=planar_3.3v status=1i,value=3.28 1458488465012861875
> ipmi_sensor,unit=volts,name=planar_vbat status=1i,value=3.04 1458488465013072508
> ipmi_sensor,unit=rpm,name=fan_1a_tach status=1i,value=2610 1458488465013137932