README.md
Example Input Plugin
The input plugin test UDP/TCP connections response time. It can also check response text.
Configuration:
[[inputs.net_response]]
protocol = "tcp"
address = ":80"
# TCP or UDP 'ping' given url and collect response time in seconds
[[inputs.net_response]]
## Protocol, must be "tcp" or "udp"
protocol = "tcp"
## Server address (default localhost)
address = "github.com:80"
## Set timeout
timeout = "1s"
## Optional string sent to the server
send = "ssh"
## Optional expected string in answer
expect = "ssh"
## Set read timeout (only used if expecting a response)
read_timeout = "1s"
[[inputs.net_response]]
protocol = "udp"
address = "localhost:161"
timeout = "2s"
Measurements & Fields:
- net_response
- response_time (float, seconds)
- string_found (bool) # Only if "expected: option is set
Tags:
- All measurements have the following tags:
- server
- port
- protocol
Example Output:
$ ./telegraf -config telegraf.conf -input-filter net_response -test
net_response,server=192.168.2.2,port=22,protocol=tcp response_time=0.18070360500000002,string_found=true 1454785464182527094
net_response,server=192.168.2.2,port=2222,protocol=tcp response_time=1.090124776,string_found=false 1454784433658942325