telegraf/plugins/inputs/ipmi_sensor
Jonathan G b93460dd06 Split multiple sensor keys in ipmi input (#4450) 2018-07-31 17:56:03 -06:00
..
README.md
connection.go
connection_test.go
ipmi.go
ipmi_test.go

README.md

IPMI Sensor Input Plugin

Get bare metal metrics using the command line utility ipmitool.

If no servers are specified, the plugin will query the local machine sensor stats via the following command:

ipmitool sdr

or with the version 2 schema:

ipmitool sdr elist

When one or more servers are specified, the plugin will use the following command to collect remote host sensor stats:

ipmitool -I lan -H SERVER -U USERID -P PASSW0RD sdr

Configuration

# Read metrics from the bare metal servers via IPMI
[[inputs.ipmi_sensor]]
  ## optionally specify the path to the ipmitool executable
  # path = "/usr/bin/ipmitool"
  ##
  ## optionally force session privilege level. Can be CALLBACK, USER, OPERATOR, ADMINISTRATOR
  # privilege = "ADMINISTRATOR"
  ##
  ## optionally specify one or more servers via a url matching
  ##  [username[:password]@][protocol[(address)]]
  ##  e.g.
  ##    root:passwd@lan(127.0.0.1)
  ##
  ## if no servers are specified, local machine sensor stats will be queried
  ##
  # servers = ["USERID:PASSW0RD@lan(192.168.1.1)"]

  ## Recomended: use metric 'interval' that is a multiple of 'timeout' to avoid
  ## gaps or overlap in pulled data
  interval = "30s"

  ## Timeout for the ipmitool command to complete. Default is 20 seconds.
  timeout = "20s"

  ## Schema Version: (Optional, defaults to version 1)
  metric_version = 2

Measurements

Version 1 schema:

  • ipmi_sensor:
    • tags:
      • name
      • unit
      • host
      • server (only when retrieving stats from remote servers)
    • fields:
      • status (int, 1=ok status_code/0=anything else)
      • value (float)

Version 2 schema:

  • ipmi_sensor:
    • tags:
      • name
      • entity_id (can help uniquify duplicate names)
      • status_code (two letter code from IPMI documentation)
      • status_desc (extended status description field)
      • unit (only on analog values)
      • host
      • server (only when retrieving stats from remote)
    • fields:
      • value (float)

Permissions

When gathering from the local system, Telegraf will need permission to the ipmi device node. When using udev you can create the device node giving rw permissions to the telegraf user by adding the following rule to /etc/udev/rules.d/52-telegraf-ipmi.rules:

KERNEL=="ipmi*", MODE="660", GROUP="telegraf"

Example Output

Version 1 Schema

When retrieving stats from a remote server:

ipmi_sensor,server=10.20.2.203,name=uid_light value=0,status=1i 1517125513000000000
ipmi_sensor,server=10.20.2.203,name=sys._health_led status=1i,value=0 1517125513000000000
ipmi_sensor,server=10.20.2.203,name=power_supply_1,unit=watts status=1i,value=110 1517125513000000000
ipmi_sensor,server=10.20.2.203,name=power_supply_2,unit=watts status=1i,value=120 1517125513000000000
ipmi_sensor,server=10.20.2.203,name=power_supplies value=0,status=1i 1517125513000000000
ipmi_sensor,server=10.20.2.203,name=fan_1,unit=percent status=1i,value=43.12 1517125513000000000

When retrieving stats from the local machine (no server specified):

ipmi_sensor,name=uid_light value=0,status=1i 1517125513000000000
ipmi_sensor,name=sys._health_led status=1i,value=0 1517125513000000000
ipmi_sensor,name=power_supply_1,unit=watts status=1i,value=110 1517125513000000000
ipmi_sensor,name=power_supply_2,unit=watts status=1i,value=120 1517125513000000000
ipmi_sensor,name=power_supplies value=0,status=1i 1517125513000000000
ipmi_sensor,name=fan_1,unit=percent status=1i,value=43.12 1517125513000000000

Version 2 Schema

When retrieving stats from the local machine (no server specified):

ipmi_sensor,name=uid_light,entity_id=23.1,status_code=ok,status_desc=ok value=0 1517125474000000000
ipmi_sensor,name=sys._health_led,entity_id=23.2,status_code=ok,status_desc=ok value=0 1517125474000000000
ipmi_sensor,entity_id=10.1,name=power_supply_1,status_code=ok,status_desc=presence_detected,unit=watts value=110 1517125474000000000
ipmi_sensor,name=power_supply_2,entity_id=10.2,status_code=ok,unit=watts,status_desc=presence_detected value=125 1517125474000000000
ipmi_sensor,name=power_supplies,entity_id=10.3,status_code=ok,status_desc=fully_redundant value=0 1517125474000000000
ipmi_sensor,entity_id=7.1,name=fan_1,status_code=ok,status_desc=transition_to_running,unit=percent value=43.12 1517125474000000000