SNMP Plugin
The SNMP input plugin gathers metrics from SNMP agents.
Configuration:
Example:
SNMP data:
.1.0.0.0.1.1.0 octet_str "foo"
.1.0.0.0.1.1.1 octet_str "bar"
.1.0.0.0.1.102 octet_str "bad"
.1.0.0.0.1.2.0 integer 1
.1.0.0.0.1.2.1 integer 2
.1.0.0.0.1.3.0 octet_str "0.123"
.1.0.0.0.1.3.1 octet_str "0.456"
.1.0.0.0.1.3.2 octet_str "9.999"
.1.0.0.1.1 octet_str "baz"
.1.0.0.1.2 uinteger 54321
.1.0.0.1.3 uinteger 234
Telegraf config:
[[inputs.snmp]]
agents = [ "127.0.0.1:161" ]
version = 2
community = "public"
name = "system"
[[inputs.snmp.field]]
name = "hostname"
oid = ".1.0.0.1.1"
is_tag = true
[[inputs.snmp.field]]
name = "uptime"
oid = ".1.0.0.1.2"
[[inputs.snmp.field]]
name = "loadavg"
oid = ".1.0.0.1.3"
conversion = "float(2)"
[[inputs.snmp.table]]
name = "remote_servers"
inherit_tags = [ "hostname" ]
[[inputs.snmp.table.field]]
name = "server"
oid = ".1.0.0.0.1.1"
is_tag = true
[[inputs.snmp.table.field]]
name = "connections"
oid = ".1.0.0.0.1.2"
[[inputs.snmp.table.field]]
name = "latency"
oid = ".1.0.0.0.1.3"
conversion = "float"
Resulting output:
* Plugin: snmp, Collection 1
> system,agent_host=127.0.0.1,host=mylocalhost,hostname=baz loadavg=2.34,uptime=54321i 1468953135000000000
> remote_servers,agent_host=127.0.0.1,host=mylocalhost,hostname=baz,server=foo connections=1i,latency=0.123 1468953135000000000
> remote_servers,agent_host=127.0.0.1,host=mylocalhost,hostname=baz,server=bar connections=2i,latency=0.456 1468953135000000000
Configuration via MIB:
This example uses the SNMP data above, but is configured via the MIB.
The example MIB file can be found in the testdata
directory. See the MIB lookups section for more information.
Telegraf config:
[[inputs.snmp]]
agents = [ "127.0.0.1:161" ]
version = 2
community = "public"
[[inputs.snmp.field]]
oid = "TEST::hostname"
is_tag = true
[[inputs.snmp.table]]
oid = "TEST::testTable"
inherit_tags = "hostname"
Resulting output:
* Plugin: snmp, Collection 1
> testTable,agent_host=127.0.0.1,host=mylocalhost,hostname=baz,server=foo connections=1i,latency="0.123" 1468953135000000000
> testTable,agent_host=127.0.0.1,host=mylocalhost,hostname=baz,server=bar connections=2i,latency="0.456" 1468953135000000000
Config parameters
-
agents
: Default:[]
List of SNMP agents to connect to in the form ofIP[:PORT]
. If:PORT
is unspecified, it defaults to161
. -
version
: Default:2
SNMP protocol version to use. -
community
: Default:"public"
SNMP community to use. -
max_repetitions
: Default:50
Maximum number of iterations for repeating variables. -
sec_name
:
Security name for authenticated SNMPv3 requests. -
auth_protocol
: Values:"MD5"
,"SHA"
,""
. Default:""
Authentication protocol for authenticated SNMPv3 requests. -
auth_password
:
Authentication password for authenticated SNMPv3 requests. -
sec_level
: Values:"noAuthNoPriv"
,"authNoPriv"
,"authPriv"
. Default:"noAuthNoPriv"
Security level used for SNMPv3 messages. -
context_name
:
Context name used for SNMPv3 requests. -
priv_protocol
: Values:"DES"
,"AES"
,""
. Default:""
Privacy protocol used for encrypted SNMPv3 messages. -
priv_password
:
Privacy password used for encrypted SNMPv3 messages. -
name
:
Output measurement name.
Field parameters:
-
oid
:
OID to get. May be a numeric or textual OID. -
name
:
Output field/tag name. If not specified, it defaults to the value ofoid
. Ifoid
is numeric, an attempt to translate the numeric OID into a texual OID will be made. -
is_tag
:
Output this field as a tag. -
conversion
: Values:"float(X)"
,"float"
,"int"
,""
. Default:""
Converts the value according to the given specification.float(X)
: Converts the input value into a float and divides by the Xth power of 10. Efficively just moves the decimal left X places. For example a value of123
withfloat(2)
will result in1.23
.float
: Converts the value into a float with no adjustment. Same asfloat(0)
.int
: Convertes the value into an integer.
Table parameters:
-
oid
:
Automatically populates the table's fields using data from the MIB. -
name
:
Output measurement name. If not specified, it defaults to the value ofoid
. Ifoid
is numeric, an attempt to translate the numeric OID into a texual OID will be made. -
inherit_tags
:
Which tags to inherit from the top-level config and to use in the output of this table's measurement.
MIB lookups
If the plugin is configured such that it needs to perform lookups from the MIB, it will use the net-snmp utilities snmptranslate
and snmptable
.
When performing the lookups, the plugin will load all available MIBs. If your MIB files are in a custom path, you may add the path using the MIBDIRS
environment variable. See man 1 snmpcmd
for more information on the variable.