dd537b3382
Many of the examples provided within documentation are using a single dash for the command line arguments, but the telegraf executable explicitly has two dashes. There are also some inconsistencies with the ordering of the command line argument examples. I've ordered them so that the examples will show: config, config-directory, input-filter, test |
||
---|---|---|
.. | ||
README.md | ||
sensors.go | ||
sensors_notlinux.go | ||
sensors_test.go |
README.md
sensors Input Plugin
Collect lm-sensors metrics - requires the lm-sensors package installed.
This plugin collects sensor metrics with the sensors
executable from the lm-sensor package.
Configuration:
# Monitor sensors, requires lm-sensors package
[[inputs.sensors]]
## Remove numbers from field names.
## If true, a field name like 'temp1_input' will be changed to 'temp_input'.
# remove_numbers = true
Measurements & Fields:
Fields are created dynamicaly depending on the sensors. All fields are float.
Tags:
- All measurements have the following tags:
- chip
- feature
Example Output:
Default
$ telegraf --config telegraf.conf --input-filter sensors --test
* Plugin: sensors, Collection 1
> sensors,chip=power_meter-acpi-0,feature=power1 power_average=0,power_average_interval=300 1466751326000000000
> sensors,chip=k10temp-pci-00c3,feature=temp1 temp_crit=70,temp_crit_hyst=65,temp_input=29,temp_max=70 1466751326000000000
> sensors,chip=k10temp-pci-00cb,feature=temp1 temp_input=29,temp_max=70 1466751326000000000
> sensors,chip=k10temp-pci-00d3,feature=temp1 temp_input=27.5,temp_max=70 1466751326000000000
> sensors,chip=k10temp-pci-00db,feature=temp1 temp_crit=70,temp_crit_hyst=65,temp_input=29.5,temp_max=70 1466751326000000000
With remove_numbers=false
* Plugin: sensors, Collection 1
> sensors,chip=power_meter-acpi-0,feature=power1 power1_average=0,power1_average_interval=300 1466753424000000000
> sensors,chip=k10temp-pci-00c3,feature=temp1 temp1_crit=70,temp1_crit_hyst=65,temp1_input=29.125,temp1_max=70 1466753424000000000
> sensors,chip=k10temp-pci-00cb,feature=temp1 temp1_input=29,temp1_max=70 1466753424000000000
> sensors,chip=k10temp-pci-00d3,feature=temp1 temp1_input=29.5,temp1_max=70 1466753424000000000
> sensors,chip=k10temp-pci-00db,feature=temp1 temp1_crit=70,temp1_crit_hyst=65,temp1_input=30,temp1_max=70 1466753424000000000