telegraf/plugins/inputs/ipmi/ipmi_test.go

190 lines
6.4 KiB
Go

// ipmi_test
package ipmi
import (
"testing"
"github.com/influxdata/telegraf/testutil"
"github.com/stretchr/testify/assert"
"github.com/stretchr/testify/require"
)
const serv = "USERID:PASSW0RD@lan(192.168.1.1)"
const cmdReturn = `
Ambient Temp | 20 degrees C | ok
Altitude | 80 feet | ok
Avg Power | 210 Watts | ok
Planar 3.3V | 3.29 Volts | ok
Planar 5V | 4.90 Volts | ok
Planar 12V | 12.04 Volts | ok
Planar VBAT | 3.05 Volts | ok
Fan 1A Tach | 2610 RPM | ok
Fan 1B Tach | 1775 RPM | ok
Fan 2A Tach | 2001 RPM | ok
Fan 2B Tach | 1275 RPM | ok
Fan 3A Tach | 2929 RPM | ok
Fan 3B Tach | 2125 RPM | ok
Fan 1 | 0x00 | ok
Fan 2 | 0x00 | ok
Fan 3 | 0x00 | ok
Front Panel | 0x00 | ok
Video USB | 0x00 | ok
DASD Backplane 1 | 0x00 | ok
SAS Riser | 0x00 | ok
PCI Riser 1 | 0x00 | ok
PCI Riser 2 | 0x00 | ok
CPU 1 | 0x00 | ok
CPU 2 | 0x00 | ok
All CPUs | 0x00 | ok
One of The CPUs | 0x00 | ok
IOH Temp Status | 0x00 | ok
CPU 1 OverTemp | 0x00 | ok
CPU 2 OverTemp | 0x00 | ok
CPU Fault Reboot | 0x00 | ok
Aux Log | 0x00 | ok
NMI State | 0x00 | ok
ABR Status | 0x00 | ok
Firmware Error | 0x00 | ok
PCIs | 0x00 | ok
CPUs | 0x00 | ok
DIMMs | 0x00 | ok
Sys Board Fault | 0x00 | ok
Power Supply 1 | 0x00 | ok
Power Supply 2 | 0x00 | ok
PS 1 Fan Fault | 0x00 | ok
PS 2 Fan Fault | 0x00 | ok
VT Fault | 0x00 | ok
Pwr Rail A Fault | 0x00 | ok
Pwr Rail B Fault | 0x00 | ok
Pwr Rail C Fault | 0x00 | ok
Pwr Rail D Fault | 0x00 | ok
Pwr Rail E Fault | 0x00 | ok
PS 1 Therm Fault | 0x00 | ok
PS 2 Therm Fault | 0x00 | ok
PS1 12V OV Fault | 0x00 | ok
PS2 12V OV Fault | 0x00 | ok
PS1 12V UV Fault | 0x00 | ok
PS2 12V UV Fault | 0x00 | ok
PS1 12V OC Fault | 0x00 | ok
PS2 12V OC Fault | 0x00 | ok
PS 1 VCO Fault | 0x00 | ok
PS 2 VCO Fault | 0x00 | ok
Power Unit | 0x00 | ok
Cooling Zone 1 | 0x00 | ok
Cooling Zone 2 | 0x00 | ok
Cooling Zone 3 | 0x00 | ok
Drive 0 | 0x00 | ok
Drive 1 | 0x00 | ok
Drive 2 | 0x00 | ok
Drive 3 | 0x00 | ok
Drive 4 | 0x00 | ok
Drive 5 | 0x00 | ok
Drive 6 | 0x00 | ok
Drive 7 | 0x00 | ok
Drive 8 | 0x00 | ok
Drive 9 | 0x00 | ok
Drive 10 | 0x00 | ok
Drive 11 | 0x00 | ok
Drive 12 | 0x00 | ok
Drive 13 | 0x00 | ok
Drive 14 | 0x00 | ok
Drive 15 | 0x00 | ok
All DIMMS | 0x00 | ok
One of the DIMMs | 0x00 | ok
DIMM 1 | 0x00 | ok
DIMM 2 | 0x00 | ok
DIMM 3 | 0x00 | ok
DIMM 4 | 0x00 | ok
DIMM 5 | 0x00 | ok
DIMM 6 | 0x00 | ok
DIMM 7 | 0x00 | ok
DIMM 8 | 0x00 | ok
DIMM 9 | 0x00 | ok
DIMM 10 | 0x00 | ok
DIMM 11 | 0x00 | ok
DIMM 12 | 0x00 | ok
DIMM 13 | 0x00 | ok
DIMM 14 | 0x00 | ok
DIMM 15 | 0x00 | ok
DIMM 16 | 0x00 | ok
DIMM 17 | 0x00 | ok
DIMM 18 | 0x00 | ok
DIMM 1 Temp | 0x00 | ok
DIMM 2 Temp | 0x00 | ok
DIMM 3 Temp | 0x00 | ok
DIMM 4 Temp | 0x00 | ok
DIMM 5 Temp | 0x00 | ok
DIMM 6 Temp | 0x00 | ok
DIMM 7 Temp | 0x00 | ok
DIMM 8 Temp | 0x00 | ok
DIMM 9 Temp | 0x00 | ok
DIMM 10 Temp | 0x00 | ok
DIMM 11 Temp | 0x00 | ok
DIMM 12 Temp | 0x00 | ok
DIMM 13 Temp | 0x00 | ok
DIMM 14 Temp | 0x00 | ok
DIMM 15 Temp | 0x00 | ok
DIMM 16 Temp | 0x00 | ok
DIMM 17 Temp | 0x00 | ok
DIMM 18 Temp | 0x00 | ok
PCI 1 | 0x00 | ok
PCI 2 | 0x00 | ok
PCI 3 | 0x00 | ok
PCI 4 | 0x00 | ok
All PCI Error | 0x00 | ok
One of PCI Error | 0x00 | ok
IPMI Watchdog | 0x00 | ok
Host Power | 0x00 | ok
DASD Backplane 2 | 0x00 | ok
DASD Backplane 3 | Not Readable | ns
DASD Backplane 4 | Not Readable | ns
Backup Memory | 0x00 | ok
Progress | 0x00 | ok
Planar Fault | 0x00 | ok
SEL Fullness | 0x00 | ok
PCI 5 | 0x00 | ok
OS RealTime Mod | 0x00 | ok
`
type runnerMock struct {
out string
err error
}
func newRunnerMock(out string, err error) Runner {
return &runnerMock{
out: out,
err: err,
}
}
func (r runnerMock) Run(conn *Connection, args ...string) (out string, err error) {
if r.err != nil {
return out, r.err
}
return r.out, nil
}
func TestIpmi(t *testing.T) {
i := &Ipmi{
Servers: []string{"USERID:PASSW0RD@lan(192.168.1.1)"},
runner: newRunnerMock(cmdReturn, nil),
}
var acc testutil.Accumulator
err := i.Gather(&acc)
require.NoError(t, err)
assert.Equal(t, acc.NFields(), 266, "non-numeric measurements should be ignored")
}
func TestIpmiConnection(t *testing.T) {
conn := NewConnection(serv)
assert.Equal(t, "USERID", conn.Username)
assert.Equal(t, "lan", conn.Interface)
}