| README.md | ||
| snmp.go | ||
| snmp_test.go | ||
README.md
SNMP Plugin
The SNMP input plugin gathers metrics from SNMP agents. It is an alternative to the SNMP plugin with significantly different configuration & behavior.
Configuration:
Example:
SNMP data:
.1.2.3.0.0.1.0 octet_str "foo"
.1.2.3.0.0.1.1 octet_str "bar"
.1.2.3.0.0.102 octet_str "bad"
.1.2.3.0.0.2.0 integer 1
.1.2.3.0.0.2.1 integer 2
.1.2.3.0.0.3.0 octet_str "0.123"
.1.2.3.0.0.3.1 octet_str "0.456"
.1.2.3.0.0.3.2 octet_str "9.999"
.1.2.3.0.1 octet_str "baz"
.1.2.3.0.2 uinteger 54321
.1.2.3.0.3 uinteger 234
Telegraf config:
[[inputs.snmp]]
agents = [ "127.0.0.1:161" ]
version = 2
community = "public"
name = "system"
[[inputs.snmp.field]]
name = "hostname"
oid = ".1.2.3.0.1"
is_tag = true
[[inputs.snmp.field]]
name = "uptime"
oid = ".1.2.3.0.2"
[[inputs.snmp.field]]
name = "loadavg"
oid = ".1.2.3.0.3"
conversion = "float(2)"
[[inputs.snmp.table]]
name = "remote_servers"
inherit_tags = [ "hostname" ]
[[inputs.snmp.table.field]]
name = "server"
oid = ".1.2.3.0.0.1"
is_tag = true
[[inputs.snmp.table.field]]
name = "connections"
oid = ".1.2.3.0.0.2"
[[inputs.snmp.table.field]]
name = "latency"
oid = ".1.2.3.0.0.3"
conversion = "float"
Resulting output:
* Plugin: snmp, Collection 1
> system,agent_host=127.0.0.1,host=mylocalhost,hostname=baz loadavg=2.34,uptime=54321i 1468953135000000000
> remote_servers,agent_host=127.0.0.1,host=mylocalhost,hostname=baz,server=foo connections=1i,latency=0.123 1468953135000000000
> remote_servers,agent_host=127.0.0.1,host=mylocalhost,hostname=baz,server=bar connections=2i,latency=0.456 1468953135000000000
Config parameters
-
agents: Default:[]List of SNMP agents to connect to in the form ofIP[:PORT]. If:PORTis unspecified, it defaults to161. -
version: Default:2SNMP protocol version to use. -
community: Default:"public"SNMP community to use. -
max_repetitions: Default:50Maximum number of iterations for repeating variables. -
sec_name: Security name for authenticated SNMPv3 requests. -
auth_protocol: Values:"MD5","SHA","". Default:""Authentication protocol for authenticated SNMPv3 requests. -
auth_password: Authentication password for authenticated SNMPv3 requests. -
sec_level: Values:"noAuthNoPriv","authNoPriv","authPriv". Default:"noAuthNoPriv"Security level used for SNMPv3 messages. -
context_name: Context name used for SNMPv3 requests. -
priv_protocol: Values:"DES","AES","". Default:""Privacy protocol used for encrypted SNMPv3 messages. -
priv_password: Privacy password used for encrypted SNMPv3 messages. -
name: Output measurement name.
Field parameters:
-
name: Output field/tag name. -
oid: OID to get. Must be in dotted notation, not textual. -
is_tag: Output this field as a tag. -
conversion: Values:"float(X)","float","int","". Default:""Converts the value according to the given specification.float(X): Converts the input value into a float and divides by the Xth power of 10. Efficively just moves the decimal left X places. For example a value of123withfloat(2)will result in1.23.float: Converts the value into a float with no adjustment. Same asfloat(0).int: Convertes the value into an integer.
Table parameters:
-
name: Output measurement name. -
inherit_tags: Which tags to inherit from the top-level config and to use in the output of this table's measurement.