telegraf/docs/CONFIGURATION.md

7.1 KiB

Telegraf Configuration

Generating a Configuration File

A default Telegraf config file can be generated using the -sample-config flag: telegraf -sample-config > telegraf.conf

To generate a file with specific inputs and outputs, you can use the -input-filter and -output-filter flags: telegraf -sample-config -input-filter cpu:mem:net:swap -output-filter influxdb:kafka

[global_tags] Configuration

Global tags can be specific in the [global_tags] section of the config file in key="value" format. All metrics being gathered on this host will be tagged with the tags specified here.

[agent] Configuration

Telegraf has a few options you can configure under the agent section of the config.

  • interval: Default data collection interval for all inputs
  • round_interval: Rounds collection interval to 'interval' ie, if interval="10s" then always collect on :00, :10, :20, etc.
  • metric_buffer_limit: Telegraf will cache metric_buffer_limit metrics for each output, and will flush this buffer on a successful write.
  • collection_jitter: Collection jitter is used to jitter the collection by a random amount. Each plugin will sleep for a random time within jitter before collecting. This can be used to avoid many plugins querying things like sysfs at the same time, which can have a measurable effect on the system.
  • flush_interval: Default data flushing interval for all outputs. You should not set this below interval. Maximum flush_interval will be flush_interval + flush_jitter
  • flush_jitter: Jitter the flush interval by a random amount. This is primarily to avoid large write spikes for users running a large number of telegraf instances. ie, a jitter of 5s and flush_interval 10s means flushes will happen every 10-15s.
  • debug: Run telegraf in debug mode.
  • quiet: Run telegraf in quiet mode.
  • hostname: Override default hostname, if empty use os.Hostname().

[inputs.xxx] Configuration

There are some configuration options that are configurable per input:

  • name_override: Override the base name of the measurement. (Default is the name of the input).
  • name_prefix: Specifies a prefix to attach to the measurement name.
  • name_suffix: Specifies a suffix to attach to the measurement name.
  • tags: A map of tags to apply to a specific input's measurements.
  • interval: How often to gather this metric. Normal plugins use a single global interval, but if one particular input should be run less or more often, you can configure that here.

Input Filters

There are also filters that can be configured per input:

  • namepass: An array of strings that is used to filter metrics generated by the current input. Each string in the array is tested as a glob match against measurement names and if it matches, the field is emitted.
  • namedrop: The inverse of pass, if a measurement name matches, it is not emitted.
  • fieldpass: An array of strings that is used to filter metrics generated by the current input. Each string in the array is tested as a glob match against field names and if it matches, the field is emitted.
  • fielddrop: The inverse of pass, if a field name matches, it is not emitted.
  • tagpass: tag names and arrays of strings that are used to filter measurements by the current input. Each string in the array is tested as a glob match against the tag name, and if it matches the measurement is emitted.
  • tagdrop: The inverse of tagpass. If a tag matches, the measurement is not emitted. This is tested on measurements that have passed the tagpass test.

Input Configuration Examples

This is a full working config that will output CPU data to an InfluxDB instance at 192.168.59.103:8086, tagging measurements with dc="denver-1". It will output measurements at a 10s interval and will collect per-cpu data, dropping any fields which begin with time_.

[global_tags]
  dc = "denver-1"

[agent]
  interval = "10s"

# OUTPUTS
[[outputs.influxdb]]
  url = "http://192.168.59.103:8086" # required.
  database = "telegraf" # required.
  precision = "s"

# INPUTS
[[inputs.cpu]]
  percpu = true
  totalcpu = false
  # filter all fields beginning with 'time_'
  drop = ["time_*"]

Input Config: tagpass and tagdrop

[[inputs.cpu]]
  percpu = true
  totalcpu = false
  drop = ["cpu_time"]
  # Don't collect CPU data for cpu6 & cpu7
  [inputs.cpu.tagdrop]
    cpu = [ "cpu6", "cpu7" ]

[[inputs.disk]]
  [inputs.disk.tagpass]
    # tagpass conditions are OR, not AND.
    # If the (filesystem is ext4 or xfs) OR (the path is /opt or /home)
    # then the metric passes
    fstype = [ "ext4", "xfs" ]
    # Globs can also be used on the tag values
    path = [ "/opt", "/home*" ]

Input Config: fieldpass and fielddrop

# Drop all metrics for guest & steal CPU usage
[[inputs.cpu]]
  percpu = false
  totalcpu = true
  fielddrop = ["usage_guest", "usage_steal"]

# Only store inode related metrics for disks
[[inputs.disk]]
  fieldpass = ["inodes*"]

Input Config: namepass and namedrop

# Drop all metrics about containers for kubelet
[[inputs.prometheus]]
  urls = ["http://kube-node-1:4194/metrics"]
  namedrop = ["container_"]

# Only store rest client related metrics for kubelet
[[inputs.prometheus]]
  urls = ["http://kube-node-1:4194/metrics"]
  namepass = ["rest_client_"]

Input config: prefix, suffix, and override

This plugin will emit measurements with the name cpu_total

[[inputs.cpu]]
  name_suffix = "_total"
  percpu = false
  totalcpu = true

This will emit measurements with the name foobar

[[inputs.cpu]]
  name_override = "foobar"
  percpu = false
  totalcpu = true

Input config: tags

This plugin will emit measurements with two additional tags: tag1=foo and tag2=bar

[[inputs.cpu]]
  percpu = false
  totalcpu = true
  [inputs.cpu.tags]
    tag1 = "foo"
    tag2 = "bar"

Multiple inputs of the same type

Additional inputs (or outputs) of the same type can be specified, just define more instances in the config file. It is highly recommended that you utilize name_override, name_prefix, or name_suffix config options to avoid measurement collisions:

[[inputs.cpu]]
  percpu = false
  totalcpu = true

[[inputs.cpu]]
  percpu = true
  totalcpu = false
  name_override = "percpu_usage"
  drop = ["cpu_time*"]

[outputs.xxx] Configuration

Telegraf also supports specifying multiple output sinks to send data to, configuring each output sink is different, but examples can be found by running telegraf -sample-config.

Outputs also support the same configurable options as inputs (pass, drop, tagpass, tagdrop)

[[outputs.influxdb]]
  urls = [ "http://localhost:8086" ]
  database = "telegraf"
  precision = "s"
  # Drop all measurements that start with "aerospike"
  drop = ["aerospike*"]

[[outputs.influxdb]]
  urls = [ "http://localhost:8086" ]
  database = "telegraf-aerospike-data"
  precision = "s"
  # Only accept aerospike data:
  pass = ["aerospike*"]

[[outputs.influxdb]]
  urls = [ "http://localhost:8086" ]
  database = "telegraf-cpu0-data"
  precision = "s"
  # Only store measurements where the tag "cpu" matches the value "cpu0"
  [outputs.influxdb.tagpass]
    cpu = ["cpu0"]