13 KiB
Configuration
Telegraf's configuration file is written using TOML.
View the telegraf.conf config file with all available plugins.
Generating a Configuration File
A default config file can be generated by telegraf:
telegraf config > telegraf.conf
To generate a file with specific inputs and outputs, you can use the --input-filter and --output-filter flags:
telegraf --input-filter cpu:mem:net:swap --output-filter influxdb:kafka config
Environment Variables
Environment variables can be used anywhere in the config file, simply prepend them with $. For strings the variable must be within quotes (ie, "$STR_VAR"), for numbers and booleans they should be plain (ie, $INT_VAR, $BOOL_VAR)
When using the .deb
or .rpm
packages, you can define environment variables
in the /etc/default/telegraf
file.
Configuration file locations
The location of the configuration file can be set via the --config
command
line flag.
When the --config-directory
command line flag is used files ending with
.conf
in the specified directory will also be included in the Telegraf
configuration.
On most systems, the default locations are /etc/telegraf/telegraf.conf
for
the main configuration file and /etc/telegraf/telegraf.d
for the directory of
configuration files.
Global Tags
Global tags can be specified in the [global_tags]
section of the config file
in key="value" format. All metrics being gathered on this host will be tagged
with the tags specified here.
Agent Configuration
Telegraf has a few options you can configure under the [agent]
section of the
config.
-
interval: Default data collection interval for all inputs
-
round_interval: Rounds collection interval to 'interval' ie, if interval="10s" then always collect on :00, :10, :20, etc.
-
metric_batch_size: Telegraf will send metrics to output in batch of at most metric_batch_size metrics.
-
metric_buffer_limit: Telegraf will cache metric_buffer_limit metrics for each output, and will flush this buffer on a successful write. This should be a multiple of metric_batch_size and could not be less than 2 times metric_batch_size.
-
collection_jitter: Collection jitter is used to jitter the collection by a random amount. Each plugin will sleep for a random time within jitter before collecting. This can be used to avoid many plugins querying things like sysfs at the same time, which can have a measurable effect on the system.
-
flush_interval: Default data flushing interval for all outputs. You should not set this below interval. Maximum flush_interval will be flush_interval + flush_jitter
-
flush_jitter: Jitter the flush interval by a random amount. This is primarily to avoid large write spikes for users running a large number of telegraf instances. ie, a jitter of 5s and flush_interval 10s means flushes will happen every 10-15s.
-
precision: By default or when set to "0s", precision will be set to the same timestamp order as the collection interval, with the maximum being 1s. Precision will NOT be used for service inputs. It is up to each individual service input to set the timestamp at the appropriate precision. Valid time units are "ns", "us" (or "µs"), "ms", "s".
-
logfile: Specify the log file name. The empty string means to log to stderr.
-
debug: Run telegraf in debug mode.
-
quiet: Run telegraf in quiet mode (error messages only).
-
hostname: Override default hostname, if empty use os.Hostname().
-
omit_hostname: If true, do no set the "host" tag in the telegraf agent.
Input Configuration
The following config parameters are available for all inputs:
- interval: How often to gather this metric. Normal plugins use a single global interval, but if one particular input should be run less or more often, you can configure that here.
- name_override: Override the base name of the measurement. (Default is the name of the input).
- name_prefix: Specifies a prefix to attach to the measurement name.
- name_suffix: Specifies a suffix to attach to the measurement name.
- tags: A map of tags to apply to a specific input's measurements.
The metric filtering parameters can be used to limit what metrics are emitted from the input plugin.
Output Configuration
The metric filtering parameters can be used to limit what metrics are emitted from the output plugin.
Aggregator Configuration
The following config parameters are available for all aggregators:
- period: The period on which to flush & clear each aggregator. All metrics that are sent with timestamps outside of this period will be ignored by the aggregator.
- delay: The delay before each aggregator is flushed. This is to control how long for aggregators to wait before receiving metrics from input plugins, in the case that aggregators are flushing and inputs are gathering on the same interval.
- drop_original: If true, the original metric will be dropped by the aggregator and will not get sent to the output plugins.
- name_override: Override the base name of the measurement. (Default is the name of the input).
- name_prefix: Specifies a prefix to attach to the measurement name.
- name_suffix: Specifies a suffix to attach to the measurement name.
- tags: A map of tags to apply to a specific input's measurements.
The metric filtering parameters can be used to limit what metrics are handled by the aggregator. Excluded metrics are passed downstream to the next aggregator.
Processor Configuration
The following config parameters are available for all processors:
- order: This is the order in which the processor(s) get executed. If this is not specified then processor execution order will be random.
The metric filtering parameters can be used to limit what metrics are handled by the processor. Excluded metrics are passed downstream to the next processor.
Metric Filtering
Metric filtering can be configured per plugin on any input, output, processor, and aggregator plugin. Filters fall under two categories: Selectors and Modifiers.
Selectors
Selector filters include or exclude entire metrics. When a metric is excluded from a Input or an Output plugin, the metric is dropped. If a metric is excluded from a Processor or Aggregator plugin, it is skips the plugin and is sent onwards to the next stage of processing.
-
namepass: An array of glob pattern strings. Only metrics whose measurement name matches a pattern in this list are emitted.
-
namedrop: The inverse of
namepass
. If a match is found the metric is discarded. This is tested on metrics after they have passed thenamepass
test. -
tagpass: A table mapping tag keys to arrays of glob pattern strings. Only metrics that contain a tag key in the table and a tag value matching one of its patterns is emitted.
-
tagdrop: The inverse of
tagpass
. If a match is found the metric is discarded. This is tested on metrics after they have passed thetagpass
test.
Modifiers
Modifier filters remove tags and fields from a metric. If all fields are removed the metric is removed.
-
fieldpass: An array of glob pattern strings. Only fields whose field key matches a pattern in this list are emitted.
-
fielddrop: The inverse of
fieldpass
. Fields with a field key matching one of the patterns will be discarded from the metric. This is tested on metrics after they have passed thefieldpass
test. -
taginclude: An array of glob pattern strings. Only tags with a tag key matching one of the patterns are emitted. In contrast to
tagpass
, which will pass an entire metric based on its tag,taginclude
removes all non matching tags from the metric. Any tag can be filtered including global tags and the agenthost
tag. -
tagexclude: The inverse of
taginclude
. Tags with a tag key matching one of the patterns will be discarded from the metric. Any tag can be filtered including global tags and the agenthost
tag.
Input Configuration Examples
This is a full working config that will output CPU data to an InfluxDB instance
at 192.168.59.103:8086, tagging measurements with dc="denver-1". It will output
measurements at a 10s interval and will collect per-cpu data, dropping any
fields which begin with time_
.
[global_tags]
dc = "denver-1"
[agent]
interval = "10s"
# OUTPUTS
[[outputs.influxdb]]
url = "http://192.168.59.103:8086" # required.
database = "telegraf" # required.
# INPUTS
[[inputs.cpu]]
percpu = true
totalcpu = false
# filter all fields beginning with 'time_'
fielddrop = ["time_*"]
Input Config: tagpass and tagdrop
NOTE tagpass
and tagdrop
parameters must be defined at the end of
the plugin definition, otherwise subsequent plugin config options will be
interpreted as part of the tagpass/tagdrop map.
[[inputs.cpu]]
percpu = true
totalcpu = false
fielddrop = ["cpu_time"]
# Don't collect CPU data for cpu6 & cpu7
[inputs.cpu.tagdrop]
cpu = [ "cpu6", "cpu7" ]
[[inputs.disk]]
[inputs.disk.tagpass]
# tagpass conditions are OR, not AND.
# If the (filesystem is ext4 or xfs) OR (the path is /opt or /home)
# then the metric passes
fstype = [ "ext4", "xfs" ]
# Globs can also be used on the tag values
path = [ "/opt", "/home*" ]
Input Config: fieldpass and fielddrop
# Drop all metrics for guest & steal CPU usage
[[inputs.cpu]]
percpu = false
totalcpu = true
fielddrop = ["usage_guest", "usage_steal"]
# Only store inode related metrics for disks
[[inputs.disk]]
fieldpass = ["inodes*"]
Input Config: namepass and namedrop
# Drop all metrics about containers for kubelet
[[inputs.prometheus]]
urls = ["http://kube-node-1:4194/metrics"]
namedrop = ["container_*"]
# Only store rest client related metrics for kubelet
[[inputs.prometheus]]
urls = ["http://kube-node-1:4194/metrics"]
namepass = ["rest_client_*"]
Input Config: taginclude and tagexclude
# Only include the "cpu" tag in the measurements for the cpu plugin.
[[inputs.cpu]]
percpu = true
totalcpu = true
taginclude = ["cpu"]
# Exclude the "fstype" tag from the measurements for the disk plugin.
[[inputs.disk]]
tagexclude = ["fstype"]
Input config: prefix, suffix, and override
This plugin will emit measurements with the name cpu_total
[[inputs.cpu]]
name_suffix = "_total"
percpu = false
totalcpu = true
This will emit measurements with the name foobar
[[inputs.cpu]]
name_override = "foobar"
percpu = false
totalcpu = true
Input config: tags
This plugin will emit measurements with two additional tags: tag1=foo
and
tag2=bar
NOTE: Order matters, the [inputs.cpu.tags]
table must be at the end of the
plugin definition.
[[inputs.cpu]]
percpu = false
totalcpu = true
[inputs.cpu.tags]
tag1 = "foo"
tag2 = "bar"
Multiple inputs of the same type
Additional inputs (or outputs) of the same type can be specified,
just define more instances in the config file. It is highly recommended that
you utilize name_override
, name_prefix
, or name_suffix
config options
to avoid measurement collisions:
[[inputs.cpu]]
percpu = false
totalcpu = true
[[inputs.cpu]]
percpu = true
totalcpu = false
name_override = "percpu_usage"
fielddrop = ["cpu_time*"]
Output Configuration Examples:
[[outputs.influxdb]]
urls = [ "http://localhost:8086" ]
database = "telegraf"
# Drop all measurements that start with "aerospike"
namedrop = ["aerospike*"]
[[outputs.influxdb]]
urls = [ "http://localhost:8086" ]
database = "telegraf-aerospike-data"
# Only accept aerospike data:
namepass = ["aerospike*"]
[[outputs.influxdb]]
urls = [ "http://localhost:8086" ]
database = "telegraf-cpu0-data"
# Only store measurements where the tag "cpu" matches the value "cpu0"
[outputs.influxdb.tagpass]
cpu = ["cpu0"]
Aggregator Configuration Examples:
This will collect and emit the min/max of the system load1 metric every 30s, dropping the originals.
[[inputs.system]]
fieldpass = ["load1"] # collects system load1 metric.
[[aggregators.minmax]]
period = "30s" # send & clear the aggregate every 30s.
drop_original = true # drop the original metrics.
[[outputs.file]]
files = ["stdout"]
This will collect and emit the min/max of the swap metrics every
30s, dropping the originals. The aggregator will not be applied
to the system load metrics due to the namepass
parameter.
[[inputs.swap]]
[[inputs.system]]
fieldpass = ["load1"] # collects system load1 metric.
[[aggregators.minmax]]
period = "30s" # send & clear the aggregate every 30s.
drop_original = true # drop the original metrics.
namepass = ["swap"] # only "pass" swap metrics through the aggregator.
[[outputs.file]]
files = ["stdout"]
Processor Configuration Examples:
Print only the metrics with cpu
as the measurement name, all metrics are
passed to the output:
[[processors.printer]]
namepass = "cpu"
[[outputs.file]]
files = ["/tmp/metrics.out"]